Pipe Flow CalculatorFlow, pressure & pipe geometry

Pipe calculators / Flow, velocity & diameter

Define the pipe. Follow the flow.

Rectangular Pipe Flow Calculator

Calculate actual flow and hydraulic diameter of a full rectangular duct.

Your pipe & operating inputs

mm
mm
m/s

Starting values are editable examples. Verify actual bore, fluid state and model assumptions. Dimension switching converts only the labelled length fields; flow and property units stay as printed.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

Q=width × height × velocity; hydraulic diameter=2 width height/(width+height).

Calculate actual flow and hydraulic diameter of a full rectangular duct.

  1. Confirm the fluid state, geometry, flow regime and units.
  2. Enter actual dimensions and justified operating conditions.
  3. Submit the form, then interpret the result with the assumptions and limits below.

The geometric hydraulic diameter alone does not choose turbulent correlations or account for corner effects.

Rectangular Pipe Flow: assumptions and applications

Calculate actual flow and hydraulic diameter of a full rectangular duct. The geometric hydraulic diameter alone does not choose turbulent correlations or account for corner effects.

Use the actual measured bore rather than assuming a nominal pipe label equals its inside diameter. Schedule, lining, corrosion and deposits can change the effective flow area. Enter the applicable fluid properties at the operating temperature.

A flow rate, velocity, pressure difference and capacity describe different physical quantities. The stated model determines which additional measurements are needed. The calculated examples below vary one input while holding all other printed values fixed.

Check the numbers

Rectangular Pipe Flow Calculator: calculated examples

These scenarios are computed with the same method as the form. They are not product recommendations, code design values or complete standards tables.

Worked example with stated inputs

Dimension units = Metric (m / mm); Internal width = 200 mm; Internal height = 100 mm; Mean velocity = 2 m/s.

OutputComputed result
Full rectangular section flow40 L/s
Hydraulic diameter133.333333 mm
Actual flow40 L/s
Actual flow144 m³/h
US gallons per minute634.012926 US gpm
Imperial gallons per minute527.926196 Imp gpm
Actual cubic feet per minute84.7552 acfm

How the stated input changes the result

ScenarioChanged input / basisResult
1 m/sMean velocity20 L/s
1.5 m/sMean velocity30 L/s
2 m/sMean velocity40 L/s
2.5 m/sMean velocity50 L/s
3 m/sMean velocity60 L/s
4 m/sMean velocity80 L/s

Unchanged inputs use: Dimension units = Metric (m / mm); Internal width = 200 mm; Internal height = 100 mm; Mean velocity = 2 m/s. Results retain the model limitations described above.

Common questions

What is the main limitation of this calculation?

The geometric hydraulic diameter alone does not choose turbulent correlations or account for corner effects.

How are the comparison-table numbers generated?

Each row changes the labelled mean velocity from the worked example. The other printed inputs remain fixed. The table uses the same Q=width × height × velocity; hydraulic diameter=2 width height/(width+height). method as the form.

How do I use this rectangular pipe flow calculator?

Calculate actual flow and hydraulic diameter of a full rectangular duct. Q=width × height × velocity; hydraulic diameter=2 width height/(width+height).

Can I calculate in metric and imperial units?

The dimension selector converts the labelled length inputs. Flow and property inputs retain their explicitly printed units. Results include related units where meaningful; US gallons and Imperial gallons are different units.

Can I export this calculation to Excel?

Calculate first, then use Export CSV for results and inputs. This is a numeric text export, not an Excel formula workbook, desktop application or certified engineering report.

What do the starting values mean?

They are editable numerical examples. Actual bore, fluid state, roughness, geometry and boundary conditions must match the installation. A calculated result is not a pressure rating or code sizing approval.

Where are the formula sources?

The sources below show plain-text addresses. Equations, examples and tables are stored in these pages; the calculator does not fetch source websites or JSON data files during use.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, supplier ratings, market prices or code limits.

  • US DOE — DOE-HDBK-1012/3-92, Thermodynamics, Heat Transfer, and Fluid Flow, Volume 3https://www.energy.gov/sites/default/files/2026-04/DOE-HDBK-1012-92_VOL3.pdf
  • NIST Guide to the SI: conversion factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors