Partially Full Pipe Flow Calculator

Calculate circular pipe area, hydraulic radius, velocity and gravity discharge at a stated fill ratio.

Your pipe & operating inputs

mm
ratio
m/m
s/m⅓

Starting values are editable examples. Verify actual bore, fluid state and model assumptions. Dimension switching converts only the labelled length fields; flow and property units stay as printed.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

Q = (1/n) A R^(2/3) √S; θ=2acos(1−2y/D), A=D²(θ−sinθ)/8, R=A/(Dθ/2).

Calculate circular pipe area, hydraulic radius, velocity and gravity discharge at a stated fill ratio.

  1. Confirm the fluid state, geometry, flow regime and units.
  2. Enter actual dimensions and justified operating conditions.
  3. Submit the form, then interpret the result with the assumptions and limits below.

Uniform free-surface flow, constant slope and roughness. No inlet control, downstream backwater, surcharge, perforation inflow or culvert routing is modeled.

Partially Full Pipe Flow: assumptions and applications

Calculate circular pipe area, hydraulic radius, velocity and gravity discharge at a stated fill ratio. Uniform free-surface flow, constant slope and roughness. No inlet control, downstream backwater, surcharge, perforation inflow or culvert routing is modeled.

Use the actual measured bore rather than assuming a nominal pipe label equals its inside diameter. Schedule, lining, corrosion and deposits can change the effective flow area. Enter the applicable fluid properties at the operating temperature.

A flow rate, velocity, pressure difference and capacity describe different physical quantities. The stated model determines which additional measurements are needed. The calculated examples below vary one input while holding all other printed values fixed.

Check the numbers

Partially Full Pipe Flow Calculator: calculated examples

These scenarios are computed with the same method as the form. They are not product recommendations, code design values or complete standards tables.

Worked example with stated inputs

Dimension units = Metric (m / mm); Actual inside diameter = 300 mm; Water depth / diameter = 0.5 ratio; Energy / uniform bed slope = 0.005 m/m; Manning roughness n (example) = 0.013 s/m⅓.

OutputComputed result
Uniform gravity discharge34.188881 L/s
Water depth150 mm
Wetted area0.035343 m²
Hydraulic radius0.075 m
Mean velocity0.967347 m/s
Actual flow34.188881 L/s
Actual flow123.079972 m³/h
US gallons per minute541.904813 US gpm
Imperial gallons per minute451.230148 Imp gpm
Actual cubic feet per minute72.442136 acfm

How the stated input changes the result

ScenarioChanged input / basisResult
0.0025 m/mEnergy / uniform bed slope24.17519 L/s
0.00375 m/mEnergy / uniform bed slope29.60844 L/s
0.005 m/mEnergy / uniform bed slope34.188881 L/s
0.00625 m/mEnergy / uniform bed slope38.224331 L/s
0.0075 m/mEnergy / uniform bed slope41.872657 L/s
0.01 m/mEnergy / uniform bed slope48.350379 L/s

Unchanged inputs use: Dimension units = Metric (m / mm); Actual inside diameter = 300 mm; Water depth / diameter = 0.5 ratio; Energy / uniform bed slope = 0.005 m/m; Manning roughness n (example) = 0.013 s/m⅓. Results retain the model limitations described above.

Common questions

Can Manning calculate pressure flow or a culvert inlet?

This implementation uses uniform free-surface geometry. It does not solve a culvert entrance, outlet submergence, flood routing or a surcharged pressurized pipe.

What is hydraulic radius for a partly full pipe?

It is the wetted area divided by the wetted perimeter. It is not generally the physical radius of the pipe.

Is half-full pipe discharge half of full-flow discharge?

Yes for the same diameter, n and slope in this uniform Manning model: hydraulic radius is the same and area is half.

Where is maximum nonpressurized circular-pipe flow?

For this ideal model it is near y/D = 0.93818, with about 1.07571 times the full-section Manning discharge.

How do I use this partially full pipe flow calculator?

Calculate circular pipe area, hydraulic radius, velocity and gravity discharge at a stated fill ratio. Q = (1/n) A R^(2/3) √S; θ=2acos(1−2y/D), A=D²(θ−sinθ)/8, R=A/(Dθ/2).

Can I calculate in metric and imperial units?

The dimension selector converts the labelled length inputs. Flow and property inputs retain their explicitly printed units. Results include related units where meaningful; US gallons and Imperial gallons are different units.

Can I export this calculation to Excel?

Calculate first, then use Export CSV for results and inputs. This is a numeric text export, not an Excel formula workbook, desktop application or certified engineering report.

What do the starting values mean?

They are editable numerical examples. Actual bore, fluid state, roughness, geometry and boundary conditions must match the installation. A calculated result is not a pressure rating or code sizing approval.

Where are the formula sources?

The sources below show plain-text addresses. Equations, examples and tables are stored in these pages; the calculator does not fetch source websites or JSON data files during use.

Can a perforated drain be modeled as an ordinary solid pipe?

Not completely. Distributed inflow, soil behavior and perforation resistance can change the system. Only uniform flow in the stated unperforated circular section is calculated here.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, supplier ratings, market prices or code limits.

  • US Bureau of Reclamation — Water Measurement Manual, Chapter 2, Section 16: Normal Flow Equations and Friction Head Losshttps://www.usbr.gov/tsc/techreferences/mands/wmm/chap02_16.html
  • Missouri DOT — Engineering Policy Guide 750.1: Open Channelshttps://epg.modot.org/index.php/750.1_Open_Channels
  • NIST Guide to the SI: conversion factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors