Pipe Flow CalculatorFlow, pressure & pipe geometry

Pipe calculators / Flow, velocity & diameter

Define the pipe. Follow the flow.

Bernoulli Pipe Pressure Calculator

Balance two-section incompressible mechanical energy and solve downstream pressure.

Your pipe & operating inputs

kPa
kg/m³
m/s
m/s
m
m
m

Starting values are editable examples. Verify actual bore, fluid state and model assumptions. Dimension switching converts only the labelled length fields; flow and property units stay as printed.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

p2=p1+ρg[Hpump−hloss−(z2−z1)+(v1²−v2²)/(2g)].

Balance two-section incompressible mechanical energy and solve downstream pressure.

  1. Confirm the fluid state, geometry, flow regime and units.
  2. Enter actual dimensions and justified operating conditions.
  3. Submit the form, then interpret the result with the assumptions and limits below.

Pressure basis is retained from the input. Loss and pump heads are supplied; no cavitation, pump curve, transients or gas compressibility model.

Bernoulli Pipe Pressure: assumptions and applications

Balance two-section incompressible mechanical energy and solve downstream pressure. Pressure basis is retained from the input. Loss and pump heads are supplied; no cavitation, pump curve, transients or gas compressibility model.

Use the actual measured bore rather than assuming a nominal pipe label equals its inside diameter. Schedule, lining, corrosion and deposits can change the effective flow area. Enter the applicable fluid properties at the operating temperature.

A flow rate, velocity, pressure difference and capacity describe different physical quantities. The stated model determines which additional measurements are needed. The calculated examples below vary one input while holding all other printed values fixed.

Check the numbers

Bernoulli Pipe Pressure Calculator: calculated examples

These scenarios are computed with the same method as the form. They are not product recommendations, code design values or complete standards tables.

Worked example with stated inputs

Upstream pressure = 200 kPa; Fluid density = 998.2 kg/m³; Upstream velocity = 1 m/s; Downstream velocity = 2 m/s; Downstream elevation minus upstream = 5 m; Entered energy head loss = 1 m; Entered added pump head = 0 m.

OutputComputed result
Downstream pressure on entered basis139.768712 kPa
Pressure change-60.231288 kPa

How the stated input changes the result

ScenarioChanged input / basisResult
100 kPaUpstream pressure39.768712 kPa
150 kPaUpstream pressure89.768712 kPa
200 kPaUpstream pressure139.768712 kPa
250 kPaUpstream pressure189.768712 kPa
300 kPaUpstream pressure239.768712 kPa
400 kPaUpstream pressure339.768712 kPa

Unchanged inputs use: Upstream pressure = 200 kPa; Fluid density = 998.2 kg/m³; Upstream velocity = 1 m/s; Downstream velocity = 2 m/s; Downstream elevation minus upstream = 5 m; Entered energy head loss = 1 m; Entered added pump head = 0 m. Results retain the model limitations described above.

Common questions

What is the main limitation of this calculation?

Pressure basis is retained from the input. Loss and pump heads are supplied; no cavitation, pump curve, transients or gas compressibility model.

How are the comparison-table numbers generated?

Each row changes the labelled upstream pressure from the worked example. The other printed inputs remain fixed. The table uses the same p2=p1+ρg[Hpump−hloss−(z2−z1)+(v1²−v2²)/(2g)]. method as the form.

How do I use this bernoulli pipe pressure calculator?

Balance two-section incompressible mechanical energy and solve downstream pressure. p2=p1+ρg[Hpump−hloss−(z2−z1)+(v1²−v2²)/(2g)].

Can I calculate in metric and imperial units?

The dimension selector converts the labelled length inputs. Flow and property inputs retain their explicitly printed units. Results include related units where meaningful; US gallons and Imperial gallons are different units.

Can I export this calculation to Excel?

Calculate first, then use Export CSV for results and inputs. This is a numeric text export, not an Excel formula workbook, desktop application or certified engineering report.

What do the starting values mean?

They are editable numerical examples. Actual bore, fluid state, roughness, geometry and boundary conditions must match the installation. A calculated result is not a pressure rating or code sizing approval.

Where are the formula sources?

The sources below show plain-text addresses. Equations, examples and tables are stored in these pages; the calculator does not fetch source websites or JSON data files during use.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, supplier ratings, market prices or code limits.

  • US DOE — DOE-HDBK-1012/3-92, Thermodynamics, Heat Transfer, and Fluid Flow, Volume 3https://www.energy.gov/sites/default/files/2026-04/DOE-HDBK-1012-92_VOL3.pdf
  • NIST Guide to the SI: conversion factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors