Pipe calculators / Flow, velocity & diameter
Define the pipe. Follow the flow.
Bernoulli Pipe Pressure Calculator
Balance two-section incompressible mechanical energy and solve downstream pressure.
Your pipe & operating inputs
Your result
Ready to calculateEnter your values and press Calculate. The result will open on the calculation page.
Published references · Clear assumptions · No sign-up
The method
Formula and calculation steps
p2=p1+ρg[Hpump−hloss−(z2−z1)+(v1²−v2²)/(2g)].
Balance two-section incompressible mechanical energy and solve downstream pressure.
- Confirm the fluid state, geometry, flow regime and units.
- Enter actual dimensions and justified operating conditions.
- Submit the form, then interpret the result with the assumptions and limits below.
Pressure basis is retained from the input. Loss and pump heads are supplied; no cavitation, pump curve, transients or gas compressibility model.
Bernoulli Pipe Pressure: assumptions and applications
Balance two-section incompressible mechanical energy and solve downstream pressure. Pressure basis is retained from the input. Loss and pump heads are supplied; no cavitation, pump curve, transients or gas compressibility model.
Use the actual measured bore rather than assuming a nominal pipe label equals its inside diameter. Schedule, lining, corrosion and deposits can change the effective flow area. Enter the applicable fluid properties at the operating temperature.
A flow rate, velocity, pressure difference and capacity describe different physical quantities. The stated model determines which additional measurements are needed. The calculated examples below vary one input while holding all other printed values fixed.
Continue with: Pipe Flow Calculator · Pipe Velocity Calculator · Pipe Diameter Calculator · Pressure Head Calculator
Check the numbers
Bernoulli Pipe Pressure Calculator: calculated examples
These scenarios are computed with the same method as the form. They are not product recommendations, code design values or complete standards tables.
Worked example with stated inputs
Upstream pressure = 200 kPa; Fluid density = 998.2 kg/m³; Upstream velocity = 1 m/s; Downstream velocity = 2 m/s; Downstream elevation minus upstream = 5 m; Entered energy head loss = 1 m; Entered added pump head = 0 m.
| Output | Computed result |
|---|---|
| Downstream pressure on entered basis | 139.768712 kPa |
| Pressure change | -60.231288 kPa |
How the stated input changes the result
| Scenario | Changed input / basis | Result |
|---|---|---|
| 100 kPa | Upstream pressure | 39.768712 kPa |
| 150 kPa | Upstream pressure | 89.768712 kPa |
| 200 kPa | Upstream pressure | 139.768712 kPa |
| 250 kPa | Upstream pressure | 189.768712 kPa |
| 300 kPa | Upstream pressure | 239.768712 kPa |
| 400 kPa | Upstream pressure | 339.768712 kPa |
Unchanged inputs use: Upstream pressure = 200 kPa; Fluid density = 998.2 kg/m³; Upstream velocity = 1 m/s; Downstream velocity = 2 m/s; Downstream elevation minus upstream = 5 m; Entered energy head loss = 1 m; Entered added pump head = 0 m. Results retain the model limitations described above.
Common questions
What is the main limitation of this calculation?
Pressure basis is retained from the input. Loss and pump heads are supplied; no cavitation, pump curve, transients or gas compressibility model.
How are the comparison-table numbers generated?
Each row changes the labelled upstream pressure from the worked example. The other printed inputs remain fixed. The table uses the same p2=p1+ρg[Hpump−hloss−(z2−z1)+(v1²−v2²)/(2g)]. method as the form.
How do I use this bernoulli pipe pressure calculator?
Balance two-section incompressible mechanical energy and solve downstream pressure. p2=p1+ρg[Hpump−hloss−(z2−z1)+(v1²−v2²)/(2g)].
Can I calculate in metric and imperial units?
The dimension selector converts the labelled length inputs. Flow and property inputs retain their explicitly printed units. Results include related units where meaningful; US gallons and Imperial gallons are different units.
Can I export this calculation to Excel?
Calculate first, then use Export CSV for results and inputs. This is a numeric text export, not an Excel formula workbook, desktop application or certified engineering report.
What do the starting values mean?
They are editable numerical examples. Actual bore, fluid state, roughness, geometry and boundary conditions must match the installation. A calculated result is not a pressure rating or code sizing approval.
Where are the formula sources?
The sources below show plain-text addresses. Equations, examples and tables are stored in these pages; the calculator does not fetch source websites or JSON data files during use.
Related calculators
Formula sources and references
References support the underlying methods and units. Chosen example inputs are not universal recommendations, supplier ratings, market prices or code limits.
- US DOE — DOE-HDBK-1012/3-92, Thermodynamics, Heat Transfer, and Fluid Flow, Volume 3https://www.energy.gov/sites/default/files/2026-04/DOE-HDBK-1012-92_VOL3.pdf
- NIST Guide to the SI: conversion factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors