Bare Pipe Heat Loss Calculator

Estimate bare-pipe surface convection and radiation at a stated surface temperature.

Your pipe & operating inputs

mm
m
°C
°C
W/(m²·K)

Starting values are editable examples. Verify actual bore, fluid state and model assumptions. Dimension switching converts only the labelled length fields; flow and property units stay as printed.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

Q=hA(Tsurface−Tair)+εσA(Tsurface,K⁴−Tsurroundings,K⁴).

Estimate bare-pipe surface convection and radiation at a stated surface temperature.

  1. Confirm the fluid state, geometry, flow regime and units.
  2. Enter actual dimensions and justified operating conditions.
  3. Submit the form, then interpret the result with the assumptions and limits below.

The entered surface temperature is not automatically the fluid temperature. Surroundings are modeled as a large isothermal enclosure with unit view factor.

Bare Pipe Heat Loss: assumptions and applications

Estimate bare-pipe surface convection and radiation at a stated surface temperature. The entered surface temperature is not automatically the fluid temperature. Surroundings are modeled as a large isothermal enclosure with unit view factor.

Use the actual measured bore rather than assuming a nominal pipe label equals its inside diameter. Schedule, lining, corrosion and deposits can change the effective flow area. Enter the applicable fluid properties at the operating temperature.

A flow rate, velocity, pressure difference and capacity describe different physical quantities. The stated model determines which additional measurements are needed. The calculated examples below vary one input while holding all other printed values fixed.

Check the numbers

Bare Pipe Heat Loss Calculator: calculated examples

These scenarios are computed with the same method as the form. They are not product recommendations, code design values or complete standards tables.

Worked example with stated inputs

Dimension units = Metric (m / mm); Outside diameter = 60.3 mm; Straight pipe length = 10 m; External surface temperature = 100 °C; Air and radiative surroundings temperature = 20 °C; Convection coefficient = 10 W/(m²·K); Surface emissivity = 0.8 .

OutputComputed result
Signed outward surface heat transfer2,546.96899 W
Convection1,515.504296 W
Radiation1,031.464694 W
Heat per metre254.696899 W/m

How the stated input changes the result

ScenarioChanged input / basisResult
5 mStraight pipe length1,273.484495 W
7.5 mStraight pipe length1,910.226743 W
10 mStraight pipe length2,546.96899 W
12.5 mStraight pipe length3,183.711238 W
15 mStraight pipe length3,820.453486 W
20 mStraight pipe length5,093.937981 W

Unchanged inputs use: Dimension units = Metric (m / mm); Outside diameter = 60.3 mm; Straight pipe length = 10 m; External surface temperature = 100 °C; Air and radiative surroundings temperature = 20 °C; Convection coefficient = 10 W/(m²·K); Surface emissivity = 0.8 . Results retain the model limitations described above.

Common questions

What is the main limitation of this calculation?

The entered surface temperature is not automatically the fluid temperature. Surroundings are modeled as a large isothermal enclosure with unit view factor.

How are the comparison-table numbers generated?

Each row changes the labelled straight pipe length from the worked example. The other printed inputs remain fixed. The table uses the same Q=hA(Tsurface−Tair)+εσA(Tsurface,K⁴−Tsurroundings,K⁴). method as the form.

How do I use this bare pipe heat loss calculator?

Estimate bare-pipe surface convection and radiation at a stated surface temperature. Q=hA(Tsurface−Tair)+εσA(Tsurface,K⁴−Tsurroundings,K⁴).

Can I calculate in metric and imperial units?

The dimension selector converts the labelled length inputs. Flow and property inputs retain their explicitly printed units. Results include related units where meaningful; US gallons and Imperial gallons are different units.

Can I export this calculation to Excel?

Calculate first, then use Export CSV for results and inputs. This is a numeric text export, not an Excel formula workbook, desktop application or certified engineering report.

What do the starting values mean?

They are editable numerical examples. Actual bore, fluid state, roughness, geometry and boundary conditions must match the installation. A calculated result is not a pressure rating or code sizing approval.

Where are the formula sources?

The sources below show plain-text addresses. Equations, examples and tables are stored in these pages; the calculator does not fetch source websites or JSON data files during use.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, supplier ratings, market prices or code limits.

  • US DOE Fundamentals Handbook 1012/2-92: Heat Transfer, HT-02 pp. 11-27https://www.energy.gov/sites/default/files/2026-04/DOE-HDBK-1012-92_VOL2.pdf
  • NIST CODATA 2022: Stefan-Boltzmann constanthttps://physics.nist.gov/cgi-bin/cuu/Value?sigma
  • NIST Guide to the SI: conversion factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors