Thin Wall Pipe Hoop Stress Calculator

Calculate ideal thin-wall membrane stresses using the inside-radius convention.

Your pipe & operating inputs

mm
mm
kPa

Starting values are editable examples. Verify actual bore, fluid state and model assumptions. Dimension switching converts only the labelled length fields; flow and property units stay as printed.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

Hoop stress=Δp rinside/t; closed-end axial stress=Δp rinside/(2t).

Calculate ideal thin-wall membrane stresses using the inside-radius convention.

  1. Confirm the fluid state, geometry, flow regime and units.
  2. Enter actual dimensions and justified operating conditions.
  3. Submit the form, then interpret the result with the assumptions and limits below.

Requires t/rinside ≤0.1. No allowable working pressure, true burst prediction, weld efficiency, corrosion allowance, fatigue or external buckling rating.

Thin Wall Pipe Hoop Stress: assumptions and applications

Calculate ideal thin-wall membrane stresses using the inside-radius convention. Requires t/rinside ≤0.1. No allowable working pressure, true burst prediction, weld efficiency, corrosion allowance, fatigue or external buckling rating.

Use the actual measured bore rather than assuming a nominal pipe label equals its inside diameter. Schedule, lining, corrosion and deposits can change the effective flow area. Enter the applicable fluid properties at the operating temperature.

A flow rate, velocity, pressure difference and capacity describe different physical quantities. The stated model determines which additional measurements are needed. The calculated examples below vary one input while holding all other printed values fixed.

Check the numbers

Thin Wall Pipe Hoop Stress Calculator: calculated examples

These scenarios are computed with the same method as the form. They are not product recommendations, code design values or complete standards tables.

Worked example with stated inputs

Dimension units = Metric (m / mm); Actual inside diameter = 100 mm; Wall thickness = 2 mm; Internal minus external pressure = 1000 kPa.

OutputComputed result
Ideal thin-wall hoop stress25 MPa
Closed-end axial stress12.5 MPa
Thickness / inside radius0.04

How the stated input changes the result

ScenarioChanged input / basisResult
500 kPaInternal minus external pressure12.5 MPa
750 kPaInternal minus external pressure18.75 MPa
1000 kPaInternal minus external pressure25 MPa
1250 kPaInternal minus external pressure31.25 MPa
1500 kPaInternal minus external pressure37.5 MPa
2000 kPaInternal minus external pressure50 MPa

Unchanged inputs use: Dimension units = Metric (m / mm); Actual inside diameter = 100 mm; Wall thickness = 2 mm; Internal minus external pressure = 1000 kPa. Results retain the model limitations described above.

Common questions

Can ideal hoop stress predict burst pressure?

It does not establish actual bursting strength or allowable working pressure. Strength data, geometry limits, weld factors, corrosion, temperature and the governing design standard are additional requirements.

What is the thin-wall check?

This page requires wall thickness divided by inside radius no greater than 0.1. Thick-cylinder stress distributions need a different model.

How do I use this thin wall pipe hoop stress calculator?

Calculate ideal thin-wall membrane stresses using the inside-radius convention. Hoop stress=Δp rinside/t; closed-end axial stress=Δp rinside/(2t).

Can I calculate in metric and imperial units?

The dimension selector converts the labelled length inputs. Flow and property inputs retain their explicitly printed units. Results include related units where meaningful; US gallons and Imperial gallons are different units.

Can I export this calculation to Excel?

Calculate first, then use Export CSV for results and inputs. This is a numeric text export, not an Excel formula workbook, desktop application or certified engineering report.

What do the starting values mean?

They are editable numerical examples. Actual bore, fluid state, roughness, geometry and boundary conditions must match the installation. A calculated result is not a pressure rating or code sizing approval.

Where are the formula sources?

The sources below show plain-text addresses. Equations, examples and tables are stored in these pages; the calculator does not fetch source websites or JSON data files during use.

Can this select wall thickness, design pressure or a hydrostatic test pressure?

No. This page evaluates ideal membrane stress for an entered wall and pressure difference only; it does not implement ASME B31, test factors or allowable design values.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, supplier ratings, market prices or code limits.

  • University of Illinois Introductory Solid Mechanics: pressure vesselshttps://mechref.engr.illinois.edu/sol/pressure.html
  • PCC Energy / RathGibson: bursting or working tubing or pipe pressureshttps://www.pccenergy.com/companies/rathgibson/rathgibson-technical-information/
  • NIST Guide to the SI: conversion factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors