Pipe Flow CalculatorFlow, pressure & pipe geometry

Pipe calculators / Stress & simplified systems

Define the pipe. Follow the flow.

Series Pipe Flow Calculator

Solve a two-pipe series system with fixed supplied Darcy factors.

Your pipe & operating inputs

m
mm
m
mm
m

Starting values are editable examples. Verify actual bore, fluid state and model assumptions. Dimension switching converts only the labelled length fields; flow and property units stay as printed.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

h=R Q²; R=fD(L/D)/(2g A²); series R=ΣR; parallel Qi=√(h/Ri).

Solve a two-pipe series system with fixed supplied Darcy factors.

  1. Confirm the fluid state, geometry, flow regime and units.
  2. Enter actual dimensions and justified operating conditions.
  3. Submit the form, then interpret the result with the assumptions and limits below.

Horizontal full-liquid system, no minor losses and constant factors. Parallel paths share endpoints; this is not a looped network, multi-branch balancing or pump curve solver.

Series Pipe Flow: assumptions and applications

Solve a two-pipe series system with fixed supplied Darcy factors. Horizontal full-liquid system, no minor losses and constant factors. Parallel paths share endpoints; this is not a looped network, multi-branch balancing or pump curve solver.

Use the actual measured bore rather than assuming a nominal pipe label equals its inside diameter. Schedule, lining, corrosion and deposits can change the effective flow area. Enter the applicable fluid properties at the operating temperature.

A flow rate, velocity, pressure difference and capacity describe different physical quantities. The stated model determines which additional measurements are needed. The calculated examples below vary one input while holding all other printed values fixed.

Check the numbers

Series Pipe Flow Calculator: calculated examples

These scenarios are computed with the same method as the form. They are not product recommendations, code design values or complete standards tables.

Worked example with stated inputs

Dimension units = Metric (m / mm); Available friction head = 10 m; Pipe 1 bore = 50 mm; Pipe 1 length = 30 m; Pipe 1 fixed Darcy factor = 0.02 ; Pipe 2 bore = 40 mm; Pipe 2 length = 20 m; Pipe 2 fixed Darcy factor = 0.02 .

OutputComputed result
Two-pipe fixed-resistance flow4.556912 L/s
Pipe 1 head loss3.29543 m
Pipe 2 head loss6.70457 m
Actual flow4.556912 L/s
Actual flow16.404884 m³/h
US gallons per minute72.228531 US gpm
Imperial gallons per minute60.142833 Imp gpm
Actual cubic feet per minute9.65555 acfm

How the stated input changes the result

ScenarioChanged input / basisResult
5 mAvailable friction head3.222224 L/s
7.5 mAvailable friction head3.946402 L/s
10 mAvailable friction head4.556912 L/s
12.5 mAvailable friction head5.094783 L/s
15 mAvailable friction head5.581055 L/s
20 mAvailable friction head6.444447 L/s

Unchanged inputs use: Dimension units = Metric (m / mm); Available friction head = 10 m; Pipe 1 bore = 50 mm; Pipe 1 length = 30 m; Pipe 1 fixed Darcy factor = 0.02 ; Pipe 2 bore = 40 mm; Pipe 2 length = 20 m; Pipe 2 fixed Darcy factor = 0.02 . Results retain the model limitations described above.

Common questions

What is the main limitation of this calculation?

Horizontal full-liquid system, no minor losses and constant factors. Parallel paths share endpoints; this is not a looped network, multi-branch balancing or pump curve solver.

How are the comparison-table numbers generated?

Each row changes the labelled available friction head from the worked example. The other printed inputs remain fixed. The table uses the same h=R Q²; R=fD(L/D)/(2g A²); series R=ΣR; parallel Qi=√(h/Ri). method as the form.

How do I use this series pipe flow calculator?

Solve a two-pipe series system with fixed supplied Darcy factors. h=R Q²; R=fD(L/D)/(2g A²); series R=ΣR; parallel Qi=√(h/Ri).

Can I calculate in metric and imperial units?

The dimension selector converts the labelled length inputs. Flow and property inputs retain their explicitly printed units. Results include related units where meaningful; US gallons and Imperial gallons are different units.

Can I export this calculation to Excel?

Calculate first, then use Export CSV for results and inputs. This is a numeric text export, not an Excel formula workbook, desktop application or certified engineering report.

What do the starting values mean?

They are editable numerical examples. Actual bore, fluid state, roughness, geometry and boundary conditions must match the installation. A calculated result is not a pressure rating or code sizing approval.

Where are the formula sources?

The sources below show plain-text addresses. Equations, examples and tables are stored in these pages; the calculator does not fetch source websites or JSON data files during use.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, supplier ratings, market prices or code limits.

  • US DOE — DOE-HDBK-1012/3-92, Thermodynamics, Heat Transfer, and Fluid Flow, Volume 3https://www.energy.gov/sites/default/files/2026-04/DOE-HDBK-1012-92_VOL3.pdf
  • US EPA — EPANET 2.2 User Manual, Chapter 3: The Network Modelhttps://raw.githubusercontent.com/USEPA/EPANET2.2/master/User_Manual/docs/3_network_model.rst
  • NIST Guide to the SI: conversion factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors