Pipe calculators / Stress & simplified systems
Define the pipe. Follow the flow.
Series Pipe Flow Calculator
Solve a two-pipe series system with fixed supplied Darcy factors.
Your pipe & operating inputs
Your result
Ready to calculateEnter your values and press Calculate. The result will open on the calculation page.
Published references · Clear assumptions · No sign-up
The method
Formula and calculation steps
h=R Q²; R=fD(L/D)/(2g A²); series R=ΣR; parallel Qi=√(h/Ri).
Solve a two-pipe series system with fixed supplied Darcy factors.
- Confirm the fluid state, geometry, flow regime and units.
- Enter actual dimensions and justified operating conditions.
- Submit the form, then interpret the result with the assumptions and limits below.
Horizontal full-liquid system, no minor losses and constant factors. Parallel paths share endpoints; this is not a looped network, multi-branch balancing or pump curve solver.
Series Pipe Flow: assumptions and applications
Solve a two-pipe series system with fixed supplied Darcy factors. Horizontal full-liquid system, no minor losses and constant factors. Parallel paths share endpoints; this is not a looped network, multi-branch balancing or pump curve solver.
Use the actual measured bore rather than assuming a nominal pipe label equals its inside diameter. Schedule, lining, corrosion and deposits can change the effective flow area. Enter the applicable fluid properties at the operating temperature.
A flow rate, velocity, pressure difference and capacity describe different physical quantities. The stated model determines which additional measurements are needed. The calculated examples below vary one input while holding all other printed values fixed.
Continue with: Thin Wall Pipe Hoop Stress Calculator · Parallel Pipe Flow Calculator · Pipe Flow Calculator · Pipe Velocity Calculator
Check the numbers
Series Pipe Flow Calculator: calculated examples
These scenarios are computed with the same method as the form. They are not product recommendations, code design values or complete standards tables.
Worked example with stated inputs
Dimension units = Metric (m / mm); Available friction head = 10 m; Pipe 1 bore = 50 mm; Pipe 1 length = 30 m; Pipe 1 fixed Darcy factor = 0.02 ; Pipe 2 bore = 40 mm; Pipe 2 length = 20 m; Pipe 2 fixed Darcy factor = 0.02 .
| Output | Computed result |
|---|---|
| Two-pipe fixed-resistance flow | 4.556912 L/s |
| Pipe 1 head loss | 3.29543 m |
| Pipe 2 head loss | 6.70457 m |
| Actual flow | 4.556912 L/s |
| Actual flow | 16.404884 m³/h |
| US gallons per minute | 72.228531 US gpm |
| Imperial gallons per minute | 60.142833 Imp gpm |
| Actual cubic feet per minute | 9.65555 acfm |
How the stated input changes the result
| Scenario | Changed input / basis | Result |
|---|---|---|
| 5 m | Available friction head | 3.222224 L/s |
| 7.5 m | Available friction head | 3.946402 L/s |
| 10 m | Available friction head | 4.556912 L/s |
| 12.5 m | Available friction head | 5.094783 L/s |
| 15 m | Available friction head | 5.581055 L/s |
| 20 m | Available friction head | 6.444447 L/s |
Unchanged inputs use: Dimension units = Metric (m / mm); Available friction head = 10 m; Pipe 1 bore = 50 mm; Pipe 1 length = 30 m; Pipe 1 fixed Darcy factor = 0.02 ; Pipe 2 bore = 40 mm; Pipe 2 length = 20 m; Pipe 2 fixed Darcy factor = 0.02 . Results retain the model limitations described above.
Common questions
What is the main limitation of this calculation?
Horizontal full-liquid system, no minor losses and constant factors. Parallel paths share endpoints; this is not a looped network, multi-branch balancing or pump curve solver.
How are the comparison-table numbers generated?
Each row changes the labelled available friction head from the worked example. The other printed inputs remain fixed. The table uses the same h=R Q²; R=fD(L/D)/(2g A²); series R=ΣR; parallel Qi=√(h/Ri). method as the form.
How do I use this series pipe flow calculator?
Solve a two-pipe series system with fixed supplied Darcy factors. h=R Q²; R=fD(L/D)/(2g A²); series R=ΣR; parallel Qi=√(h/Ri).
Can I calculate in metric and imperial units?
The dimension selector converts the labelled length inputs. Flow and property inputs retain their explicitly printed units. Results include related units where meaningful; US gallons and Imperial gallons are different units.
Can I export this calculation to Excel?
Calculate first, then use Export CSV for results and inputs. This is a numeric text export, not an Excel formula workbook, desktop application or certified engineering report.
What do the starting values mean?
They are editable numerical examples. Actual bore, fluid state, roughness, geometry and boundary conditions must match the installation. A calculated result is not a pressure rating or code sizing approval.
Where are the formula sources?
The sources below show plain-text addresses. Equations, examples and tables are stored in these pages; the calculator does not fetch source websites or JSON data files during use.
Related calculators
Formula sources and references
References support the underlying methods and units. Chosen example inputs are not universal recommendations, supplier ratings, market prices or code limits.
- US DOE — DOE-HDBK-1012/3-92, Thermodynamics, Heat Transfer, and Fluid Flow, Volume 3https://www.energy.gov/sites/default/files/2026-04/DOE-HDBK-1012-92_VOL3.pdf
- US EPA — EPANET 2.2 User Manual, Chapter 3: The Network Modelhttps://raw.githubusercontent.com/USEPA/EPANET2.2/master/User_Manual/docs/3_network_model.rst
- NIST Guide to the SI: conversion factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors