Pipe Flow CalculatorFlow, pressure & pipe geometry

Pipe calculators / Pressure loss & resistance

Define the pipe. Follow the flow.

Pipe Flow from Pressure Calculator

Solve pipe flow from pressure with flow-dependent Darcy friction and explicitly entered fluid properties.

Your pipe & operating inputs

mm
m
mm
kg/m³
mm²/s
kPa

Starting values are editable examples. Verify actual bore, fluid state and model assumptions. Dimension switching converts only the labelled length fields; flow and property units stay as printed.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

Δp = (fD L/D + ΣK) ρv²/2; Re = vD/ν. Laminar fD=64/Re; turbulent fD solves Colebrook.

Solve pipe flow from pressure with flow-dependent Darcy friction and explicitly entered fluid properties.

  1. Confirm the fluid state, geometry, flow regime and units.
  2. Enter actual dimensions and justified operating conditions.
  3. Submit the form, then interpret the result with the assumptions and limits below.

Steady, full, circular, single-phase incompressible flow. Reynolds numbers from 2000 through 4000 are deliberately rejected; this calculator does not interpolate uncertain transition flow. Roughness/diameter must not exceed 0.05.

Pipe Flow from Pressure: assumptions and applications

Solve pipe flow from pressure with flow-dependent Darcy friction and explicitly entered fluid properties. Steady, full, circular, single-phase incompressible flow. Reynolds numbers from 2000 through 4000 are deliberately rejected; this calculator does not interpolate uncertain transition flow. Roughness/diameter must not exceed 0.05.

Use the actual measured bore rather than assuming a nominal pipe label equals its inside diameter. Schedule, lining, corrosion and deposits can change the effective flow area. Enter the applicable fluid properties at the operating temperature.

A flow rate, velocity, pressure difference and capacity describe different physical quantities. The stated model determines which additional measurements are needed. The calculated examples below vary one input while holding all other printed values fixed.

Check the numbers

Pipe Flow from Pressure Calculator: calculated examples

These scenarios are computed with the same method as the form. They are not product recommendations, code design values or complete standards tables.

Worked example with stated inputs

Dimension units = Metric (m / mm); Actual inside diameter = 50 mm; Straight pipe length = 30 m; Absolute roughness (example) = 0.045 mm; Sum of minor-loss K = 0 ; Fluid density = 998.2 kg/m³; Kinematic viscosity = 1.004 mm²/s; Available friction pressure difference = 100 kPa.

OutputComputed result
Flow for available friction pressure7.899133 L/s
Pressure loss100 kPa
Pressure loss14.503774 psi
Fluid head loss10.21555 m
Mean velocity4.022996 m/s
Reynolds number200,348.381656
Darcy friction factor0.020633
Relative roughness0.0009
Actual flow7.899133 L/s
Actual flow28.43688 m³/h
US gallons per minute125.203814 US gpm
Imperial gallons per minute104.253984 Imp gpm
Actual cubic feet per minute16.737315 acfm

How the stated input changes the result

ScenarioChanged input / basisResult
15 mStraight pipe length11.283196 L/s
22.5 mStraight pipe length9.162102 L/s
30 mStraight pipe length7.899133 L/s
37.5 mStraight pipe length7.038158 L/s
45 mStraight pipe length6.403246 L/s
60 mStraight pipe length5.513229 L/s

Unchanged inputs use: Dimension units = Metric (m / mm); Actual inside diameter = 50 mm; Straight pipe length = 30 m; Absolute roughness (example) = 0.045 mm; Sum of minor-loss K = 0 ; Fluid density = 998.2 kg/m³; Kinematic viscosity = 1.004 mm²/s; Available friction pressure difference = 100 kPa. Results retain the model limitations described above.

Common questions

How do I calculate water flow from PSI and pipe size?

Enter pressure available for friction, actual inside diameter, length, roughness, local-loss K, density and viscosity. The solver finds the supported laminar or turbulent flow branch.

Does this calculate maximum pipe flow?

Only the flow for the entered pressure and model assumptions. Other limits such as allowed speed, noise, cavitation, surge and pump operation are not optimized.

Can I convert PSI directly to GPM?

Pressure alone is insufficient. This model also uses actual bore, length, roughness, minor losses, density and viscosity. Enter only the pressure available for friction after other energy terms are accounted for.

How do I use this pipe flow from pressure calculator?

Solve pipe flow from pressure with flow-dependent Darcy friction and explicitly entered fluid properties. Δp = (fD L/D + ΣK) ρv²/2; Re = vD/ν. Laminar fD=64/Re; turbulent fD solves Colebrook.

Can I calculate in metric and imperial units?

The dimension selector converts the labelled length inputs. Flow and property inputs retain their explicitly printed units. Results include related units where meaningful; US gallons and Imperial gallons are different units.

Can I export this calculation to Excel?

Calculate first, then use Export CSV for results and inputs. This is a numeric text export, not an Excel formula workbook, desktop application or certified engineering report.

What do the starting values mean?

They are editable numerical examples. Actual bore, fluid state, roughness, geometry and boundary conditions must match the installation. A calculated result is not a pressure rating or code sizing approval.

Where are the formula sources?

The sources below show plain-text addresses. Equations, examples and tables are stored in these pages; the calculator does not fetch source websites or JSON data files during use.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, supplier ratings, market prices or code limits.

  • US DOE — DOE-HDBK-1012/3-92, Thermodynamics, Heat Transfer, and Fluid Flow, Volume 3https://www.energy.gov/sites/default/files/2026-04/DOE-HDBK-1012-92_VOL3.pdf
  • US EPA — EPANET 2.2 User Manual, Chapter 12: Analysis Algorithmshttps://raw.githubusercontent.com/USEPA/EPANET2.2/master/User_Manual/docs/12_analysis_algorithms.rst
  • Brkić and Praks (2019) — Accurate and Efficient Explicit Approximations of the Colebrook Flow Friction Equation Based on the Wright ω-Functionhttps://www.mdpi.com/2227-7390/7/1/34
  • NIST Guide to the SI: conversion factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors