Pipe calculators / Pressure loss & resistance
Define the pipe. Follow the flow.
Colebrook Friction Factor Calculator
Solve the implicit turbulent Colebrook equation, or 64/Re for laminar flow.
Your pipe & operating inputs
Your result
Ready to calculateEnter your values and press Calculate. The result will open on the calculation page.
Published references · Clear assumptions · No sign-up
The method
Formula and calculation steps
1/√fD = −2 log10[(ε/D)/3.7 + 2.51/(Re√fD)].
Solve the implicit turbulent Colebrook equation, or 64/Re for laminar flow.
- Confirm the fluid state, geometry, flow regime and units.
- Enter actual dimensions and justified operating conditions.
- Submit the form, then interpret the result with the assumptions and limits below.
Outputs are Darcy factors, four times the Fanning factor. Re from 2000 through 4000 is rejected.
Colebrook Friction Factor: assumptions and applications
Solve the implicit turbulent Colebrook equation, or 64/Re for laminar flow. Outputs are Darcy factors, four times the Fanning factor. Re from 2000 through 4000 is rejected.
Use the actual measured bore rather than assuming a nominal pipe label equals its inside diameter. Schedule, lining, corrosion and deposits can change the effective flow area. Enter the applicable fluid properties at the operating temperature.
A flow rate, velocity, pressure difference and capacity describe different physical quantities. The stated model determines which additional measurements are needed. The calculated examples below vary one input while holding all other printed values fixed.
Continue with: Pipe Pressure Drop Calculator · Pipe Flow from Pressure Calculator · Pipe Head Loss Calculator · Pipe Reynolds Number Calculator
Check the numbers
Colebrook Friction Factor Calculator: calculated examples
These scenarios are computed with the same method as the form. They are not product recommendations, code design values or complete standards tables.
Worked example with stated inputs
Reynolds number = 100000 ; Relative roughness ε/D = 0.0009 .
| Output | Computed result |
|---|---|
| Darcy friction factor | 0.021832 Darcy |
| Fanning factor | 0.005458 Fanning |
How the stated input changes the result
| Scenario | Changed input / basis | Result |
|---|---|---|
| 50000 | Reynolds number | 0.023744 Darcy |
| 75000 | Reynolds number | 0.022526 Darcy |
| 100000 | Reynolds number | 0.021832 Darcy |
| 125000 | Reynolds number | 0.02138 Darcy |
| 150000 | Reynolds number | 0.02106 Darcy |
| 200000 | Reynolds number | 0.020635 Darcy |
Unchanged inputs use: Reynolds number = 100000 ; Relative roughness ε/D = 0.0009 . Results retain the model limitations described above.
Common questions
What is the main limitation of this calculation?
Outputs are Darcy factors, four times the Fanning factor. Re from 2000 through 4000 is rejected.
How are the comparison-table numbers generated?
Each row changes the labelled reynolds number from the worked example. The other printed inputs remain fixed. The table uses the same 1/√fD = −2 log10[(ε/D)/3.7 + 2.51/(Re√fD)]. method as the form.
How do I use this colebrook friction factor calculator?
Solve the implicit turbulent Colebrook equation, or 64/Re for laminar flow. 1/√fD = −2 log10[(ε/D)/3.7 + 2.51/(Re√fD)].
Can I calculate in metric and imperial units?
The dimension selector converts the labelled length inputs. Flow and property inputs retain their explicitly printed units. Results include related units where meaningful; US gallons and Imperial gallons are different units.
Can I export this calculation to Excel?
Calculate first, then use Export CSV for results and inputs. This is a numeric text export, not an Excel formula workbook, desktop application or certified engineering report.
What do the starting values mean?
They are editable numerical examples. Actual bore, fluid state, roughness, geometry and boundary conditions must match the installation. A calculated result is not a pressure rating or code sizing approval.
Where are the formula sources?
The sources below show plain-text addresses. Equations, examples and tables are stored in these pages; the calculator does not fetch source websites or JSON data files during use.
Related calculators
Formula sources and references
References support the underlying methods and units. Chosen example inputs are not universal recommendations, supplier ratings, market prices or code limits.
- Brkić and Praks (2019) — Accurate and Efficient Explicit Approximations of the Colebrook Flow Friction Equation Based on the Wright ω-Functionhttps://www.mdpi.com/2227-7390/7/1/34
- US EPA — EPANET 2.2 User Manual, Chapter 12: Analysis Algorithmshttps://raw.githubusercontent.com/USEPA/EPANET2.2/master/User_Manual/docs/12_analysis_algorithms.rst
- NIST Guide to the SI: conversion factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors