Pipe Flow CalculatorFlow, pressure & pipe geometry

Pipe calculators / Gravity drainage & Manning

Define the pipe. Follow the flow.

HDPE Gravity Pipe Flow Calculator

Estimate hdpe uniform gravity discharge at a stated depth, slope and editable n.

Your pipe & operating inputs

mm
ratio
m/m
s/m⅓

Starting values are editable examples. Verify actual bore, fluid state and model assumptions. Dimension switching converts only the labelled length fields; flow and property units stay as printed.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

Q = (1/n) A R^(2/3) √S; θ=2acos(1−2y/D), A=D²(θ−sinθ)/8, R=A/(Dθ/2).

Estimate hdpe uniform gravity discharge at a stated depth, slope and editable n.

  1. Confirm the fluid state, geometry, flow regime and units.
  2. Enter actual dimensions and justified operating conditions.
  3. Submit the form, then interpret the result with the assumptions and limits below.

Uniform free-surface flow, constant slope and roughness. No inlet control, downstream backwater, surcharge, perforation inflow or culvert routing is modeled. Smooth plastic example; actual SDR and bore depend on the specific product.

HDPE Gravity Pipe Flow: assumptions and applications

Estimate hdpe uniform gravity discharge at a stated depth, slope and editable n. Uniform free-surface flow, constant slope and roughness. No inlet control, downstream backwater, surcharge, perforation inflow or culvert routing is modeled. Smooth plastic example; actual SDR and bore depend on the specific product.

Use the actual measured bore rather than assuming a nominal pipe label equals its inside diameter. Schedule, lining, corrosion and deposits can change the effective flow area. Enter the applicable fluid properties at the operating temperature.

A flow rate, velocity, pressure difference and capacity describe different physical quantities. The stated model determines which additional measurements are needed. The calculated examples below vary one input while holding all other printed values fixed.

Check the numbers

HDPE Gravity Pipe Flow Calculator: calculated examples

These scenarios are computed with the same method as the form. They are not product recommendations, code design values or complete standards tables.

Worked example with stated inputs

Dimension units = Metric (m / mm); Actual inside diameter = 300 mm; Water depth / diameter = 0.5 ratio; Energy / uniform bed slope = 0.005 m/m; Manning roughness n (example) = 0.011 s/m⅓.

OutputComputed result
Uniform gravity discharge40.405041 L/s
Water depth150 mm
Wetted area0.035343 m²
Hydraulic radius0.075 m
Mean velocity1.143229 m/s
Actual flow40.405041 L/s
Actual flow145.458148 m³/h
US gallons per minute640.43296 US gpm
Imperial gallons per minute533.271993 Imp gpm
Actual cubic feet per minute85.613434 acfm

How the stated input changes the result

ScenarioChanged input / basisResult
0.0025 m/mEnergy / uniform bed slope28.570679 L/s
0.00375 m/mEnergy / uniform bed slope34.991792 L/s
0.005 m/mEnergy / uniform bed slope40.405041 L/s
0.00625 m/mEnergy / uniform bed slope45.174209 L/s
0.0075 m/mEnergy / uniform bed slope49.485867 L/s
0.01 m/mEnergy / uniform bed slope57.141357 L/s

Unchanged inputs use: Dimension units = Metric (m / mm); Actual inside diameter = 300 mm; Water depth / diameter = 0.5 ratio; Energy / uniform bed slope = 0.005 m/m; Manning roughness n (example) = 0.011 s/m⅓. Results retain the model limitations described above.

Common questions

Can Manning calculate pressure flow or a culvert inlet?

This implementation uses uniform free-surface geometry. It does not solve a culvert entrance, outlet submergence, flood routing or a surcharged pressurized pipe.

What is hydraulic radius for a partly full pipe?

It is the wetted area divided by the wetted perimeter. It is not generally the physical radius of the pipe.

How do I use this hdpe gravity pipe flow calculator?

Estimate hdpe uniform gravity discharge at a stated depth, slope and editable n. Q = (1/n) A R^(2/3) √S; θ=2acos(1−2y/D), A=D²(θ−sinθ)/8, R=A/(Dθ/2).

Can I calculate in metric and imperial units?

The dimension selector converts the labelled length inputs. Flow and property inputs retain their explicitly printed units. Results include related units where meaningful; US gallons and Imperial gallons are different units.

Can I export this calculation to Excel?

Calculate first, then use Export CSV for results and inputs. This is a numeric text export, not an Excel formula workbook, desktop application or certified engineering report.

What do the starting values mean?

They are editable numerical examples. Actual bore, fluid state, roughness, geometry and boundary conditions must match the installation. A calculated result is not a pressure rating or code sizing approval.

Where are the formula sources?

The sources below show plain-text addresses. Equations, examples and tables are stored in these pages; the calculator does not fetch source websites or JSON data files during use.

Can a perforated drain be modeled as an ordinary solid pipe?

Not completely. Distributed inflow, soil behavior and perforation resistance can change the system. Only uniform flow in the stated unperforated circular section is calculated here.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, supplier ratings, market prices or code limits.

  • US EPA — EPANET 2.2 User Manual, Chapter 3: The Network Modelhttps://raw.githubusercontent.com/USEPA/EPANET2.2/master/User_Manual/docs/3_network_model.rst
  • US Bureau of Reclamation — Water Measurement Manual, Chapter 2, Section 16: Normal Flow Equations and Friction Head Losshttps://www.usbr.gov/tsc/techreferences/mands/wmm/chap02_16.html
  • Missouri DOT — Engineering Policy Guide 750.1: Open Channelshttps://epg.modot.org/index.php/750.1_Open_Channels
  • NIST Guide to the SI: conversion factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors