Pipe Flow CalculatorFlow, pressure & pipe geometry

Pipe calculators / Pressure loss & resistance

Define the pipe. Follow the flow.

Laminar Pipe Flow Calculator

Calculate fully developed laminar Newtonian flow by Hagen-Poiseuille.

Your pipe & operating inputs

mm
m
kPa
Pa·s
kg/m³

Starting values are editable examples. Verify actual bore, fluid state and model assumptions. Dimension switching converts only the labelled length fields; flow and property units stay as printed.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

Q=π Δp D⁴/(128 μL); Re=ρvD/μ.

Calculate fully developed laminar Newtonian flow by Hagen-Poiseuille.

  1. Confirm the fluid state, geometry, flow regime and units.
  2. Enter actual dimensions and justified operating conditions.
  3. Submit the form, then interpret the result with the assumptions and limits below.

Rigid circular bore, incompressible Newtonian fluid, no entrance or fittings. Results with Re≥2000 are rejected.

Laminar Pipe Flow: assumptions and applications

Calculate fully developed laminar Newtonian flow by Hagen-Poiseuille. Rigid circular bore, incompressible Newtonian fluid, no entrance or fittings. Results with Re≥2000 are rejected.

Use the actual measured bore rather than assuming a nominal pipe label equals its inside diameter. Schedule, lining, corrosion and deposits can change the effective flow area. Enter the applicable fluid properties at the operating temperature.

A flow rate, velocity, pressure difference and capacity describe different physical quantities. The stated model determines which additional measurements are needed. The calculated examples below vary one input while holding all other printed values fixed.

Check the numbers

Laminar Pipe Flow Calculator: calculated examples

These scenarios are computed with the same method as the form. They are not product recommendations, code design values or complete standards tables.

Worked example with stated inputs

Dimension units = Metric (m / mm); Actual inside diameter = 10 mm; Straight pipe length = 10 m; Friction pressure difference = 1 kPa; Dynamic viscosity = 0.1 Pa·s; Fluid density = 900 kg/m³.

OutputComputed result
Fully developed laminar flow0.000245 L/s
Reynolds number0.28125
Actual flow0.000245 L/s
Actual flow0.000884 m³/h
US gallons per minute0.00389 US gpm
Imperial gallons per minute0.003239 Imp gpm
Actual cubic feet per minute0.00052 acfm

How the stated input changes the result

ScenarioChanged input / basisResult
0.5 kPaFriction pressure difference0.000123 L/s
0.75 kPaFriction pressure difference0.000184 L/s
1 kPaFriction pressure difference0.000245 L/s
1.25 kPaFriction pressure difference0.000307 L/s
1.5 kPaFriction pressure difference0.000368 L/s
2 kPaFriction pressure difference0.000491 L/s

Unchanged inputs use: Dimension units = Metric (m / mm); Actual inside diameter = 10 mm; Straight pipe length = 10 m; Friction pressure difference = 1 kPa; Dynamic viscosity = 0.1 Pa·s; Fluid density = 900 kg/m³. Results retain the model limitations described above.

Common questions

What is the main limitation of this calculation?

Rigid circular bore, incompressible Newtonian fluid, no entrance or fittings. Results with Re≥2000 are rejected.

How are the comparison-table numbers generated?

Each row changes the labelled friction pressure difference from the worked example. The other printed inputs remain fixed. The table uses the same Q=π Δp D⁴/(128 μL); Re=ρvD/μ. method as the form.

How do I use this laminar pipe flow calculator?

Calculate fully developed laminar Newtonian flow by Hagen-Poiseuille. Q=π Δp D⁴/(128 μL); Re=ρvD/μ.

Can I calculate in metric and imperial units?

The dimension selector converts the labelled length inputs. Flow and property inputs retain their explicitly printed units. Results include related units where meaningful; US gallons and Imperial gallons are different units.

Can I export this calculation to Excel?

Calculate first, then use Export CSV for results and inputs. This is a numeric text export, not an Excel formula workbook, desktop application or certified engineering report.

What do the starting values mean?

They are editable numerical examples. Actual bore, fluid state, roughness, geometry and boundary conditions must match the installation. A calculated result is not a pressure rating or code sizing approval.

Where are the formula sources?

The sources below show plain-text addresses. Equations, examples and tables are stored in these pages; the calculator does not fetch source websites or JSON data files during use.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, supplier ratings, market prices or code limits.

  • US DOE — DOE-HDBK-1012/3-92, Thermodynamics, Heat Transfer, and Fluid Flow, Volume 3https://www.energy.gov/sites/default/files/2026-04/DOE-HDBK-1012-92_VOL3.pdf
  • US EPA — EPANET 2.2 User Manual, Chapter 12: Analysis Algorithmshttps://raw.githubusercontent.com/USEPA/EPANET2.2/master/User_Manual/docs/12_analysis_algorithms.rst
  • NIST Guide to the SI: conversion factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors