Pipe Flow CalculatorFlow, pressure & pipe geometry

Pipe calculators / Pressure loss & resistance

Define the pipe. Follow the flow.

Hazen Williams Pipe Flow Calculator

Calculate water head loss with the empirical Hazen-Williams relation.

Your pipe & operating inputs

mm
m
L/s

Starting values are editable examples. Verify actual bore, fluid state and model assumptions. Dimension switching converts only the labelled length fields; flow and property units stay as printed.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

h = 10.67 L Q^1.852 /(C^1.852 D^4.8704), SI Q in m³/s and D in m.

Calculate water head loss with the empirical Hazen-Williams relation.

  1. Confirm the fluid state, geometry, flow regime and units.
  2. Enter actual dimensions and justified operating conditions.
  3. Submit the form, then interpret the result with the assumptions and limits below.

Water only, turbulent normal water-service conditions. C is user supplied and changes with condition and age; do not use for gas or viscous oil.

Hazen Williams Pipe Flow: assumptions and applications

Calculate water head loss with the empirical Hazen-Williams relation. Water only, turbulent normal water-service conditions. C is user supplied and changes with condition and age; do not use for gas or viscous oil.

Use the actual measured bore rather than assuming a nominal pipe label equals its inside diameter. Schedule, lining, corrosion and deposits can change the effective flow area. Enter the applicable fluid properties at the operating temperature.

A flow rate, velocity, pressure difference and capacity describe different physical quantities. The stated model determines which additional measurements are needed. The calculated examples below vary one input while holding all other printed values fixed.

Check the numbers

Hazen Williams Pipe Flow Calculator: calculated examples

These scenarios are computed with the same method as the form. They are not product recommendations, code design values or complete standards tables.

Worked example with stated inputs

Dimension units = Metric (m / mm); Actual inside diameter = 100 mm; Straight pipe length = 100 m; Actual volume flow = 10 L/s; Hazen-Williams C (example) = 140 .

OutputComputed result
Hazen-Williams water head loss1.65934 m head
Mean velocity1.27324 m/s

How the stated input changes the result

ScenarioChanged input / basisResult
5 L/sActual volume flow0.459651 m head
7.5 L/sActual volume flow0.973977 m head
10 L/sActual volume flow1.65934 m head
12.5 L/sActual volume flow2.508492 m head
15 L/sActual volume flow3.51606 m head
20 L/sActual volume flow5.990221 m head

Unchanged inputs use: Dimension units = Metric (m / mm); Actual inside diameter = 100 mm; Straight pipe length = 100 m; Actual volume flow = 10 L/s; Hazen-Williams C (example) = 140 . Results retain the model limitations described above.

Common questions

What is the main limitation of this calculation?

Water only, turbulent normal water-service conditions. C is user supplied and changes with condition and age; do not use for gas or viscous oil.

How are the comparison-table numbers generated?

Each row changes the labelled actual volume flow from the worked example. The other printed inputs remain fixed. The table uses the same h = 10.67 L Q^1.852 /(C^1.852 D^4.8704), SI Q in m³/s and D in m. method as the form.

How do I use this hazen williams pipe flow calculator?

Calculate water head loss with the empirical Hazen-Williams relation. h = 10.67 L Q^1.852 /(C^1.852 D^4.8704), SI Q in m³/s and D in m.

Can I calculate in metric and imperial units?

The dimension selector converts the labelled length inputs. Flow and property inputs retain their explicitly printed units. Results include related units where meaningful; US gallons and Imperial gallons are different units.

Can I export this calculation to Excel?

Calculate first, then use Export CSV for results and inputs. This is a numeric text export, not an Excel formula workbook, desktop application or certified engineering report.

What do the starting values mean?

They are editable numerical examples. Actual bore, fluid state, roughness, geometry and boundary conditions must match the installation. A calculated result is not a pressure rating or code sizing approval.

Where are the formula sources?

The sources below show plain-text addresses. Equations, examples and tables are stored in these pages; the calculator does not fetch source websites or JSON data files during use.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, supplier ratings, market prices or code limits.

  • US EPA — EPANET 2.2 User Manual, Chapter 3: The Network Modelhttps://raw.githubusercontent.com/USEPA/EPANET2.2/master/User_Manual/docs/3_network_model.rst
  • NIST Guide to the SI: conversion factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors