The method
Formula and calculation steps
h = 10.67 L Q^1.852 /(C^1.852 D^4.8704), SI Q in m³/s and D in m.
Calculate water head loss with the empirical Hazen-Williams relation.
- Confirm the fluid state, geometry, flow regime and units.
- Enter actual dimensions and justified operating conditions.
- Submit the form, then interpret the result with the assumptions and limits below.
Water only, turbulent normal water-service conditions. C is user supplied and changes with condition and age; do not use for gas or viscous oil.
Hazen Williams Pipe Flow: assumptions and applications
Calculate water head loss with the empirical Hazen-Williams relation. Water only, turbulent normal water-service conditions. C is user supplied and changes with condition and age; do not use for gas or viscous oil.
Use the actual measured bore rather than assuming a nominal pipe label equals its inside diameter. Schedule, lining, corrosion and deposits can change the effective flow area. Enter the applicable fluid properties at the operating temperature.
A flow rate, velocity, pressure difference and capacity describe different physical quantities. The stated model determines which additional measurements are needed. The calculated examples below vary one input while holding all other printed values fixed.
Continue with: Pipe Pressure Drop Calculator · Pipe Flow from Pressure Calculator · Pipe Head Loss Calculator · Pipe Reynolds Number Calculator
Check the numbers
Hazen Williams Pipe Flow Calculator: calculated examples
These scenarios are computed with the same method as the form. They are not product recommendations, code design values or complete standards tables.
Worked example with stated inputs
Dimension units = Metric (m / mm); Actual inside diameter = 100 mm; Straight pipe length = 100 m; Actual volume flow = 10 L/s; Hazen-Williams C (example) = 140 .
| Output | Computed result |
|---|---|
| Hazen-Williams water head loss | 1.65934 m head |
| Mean velocity | 1.27324 m/s |
How the stated input changes the result
| Scenario | Changed input / basis | Result |
|---|---|---|
| 5 L/s | Actual volume flow | 0.459651 m head |
| 7.5 L/s | Actual volume flow | 0.973977 m head |
| 10 L/s | Actual volume flow | 1.65934 m head |
| 12.5 L/s | Actual volume flow | 2.508492 m head |
| 15 L/s | Actual volume flow | 3.51606 m head |
| 20 L/s | Actual volume flow | 5.990221 m head |
Unchanged inputs use: Dimension units = Metric (m / mm); Actual inside diameter = 100 mm; Straight pipe length = 100 m; Actual volume flow = 10 L/s; Hazen-Williams C (example) = 140 . Results retain the model limitations described above.
Common questions
What is the main limitation of this calculation?
Water only, turbulent normal water-service conditions. C is user supplied and changes with condition and age; do not use for gas or viscous oil.
How are the comparison-table numbers generated?
Each row changes the labelled actual volume flow from the worked example. The other printed inputs remain fixed. The table uses the same h = 10.67 L Q^1.852 /(C^1.852 D^4.8704), SI Q in m³/s and D in m. method as the form.
How do I use this hazen williams pipe flow calculator?
Calculate water head loss with the empirical Hazen-Williams relation. h = 10.67 L Q^1.852 /(C^1.852 D^4.8704), SI Q in m³/s and D in m.
Can I calculate in metric and imperial units?
The dimension selector converts the labelled length inputs. Flow and property inputs retain their explicitly printed units. Results include related units where meaningful; US gallons and Imperial gallons are different units.
Can I export this calculation to Excel?
Calculate first, then use Export CSV for results and inputs. This is a numeric text export, not an Excel formula workbook, desktop application or certified engineering report.
What do the starting values mean?
They are editable numerical examples. Actual bore, fluid state, roughness, geometry and boundary conditions must match the installation. A calculated result is not a pressure rating or code sizing approval.
Where are the formula sources?
The sources below show plain-text addresses. Equations, examples and tables are stored in these pages; the calculator does not fetch source websites or JSON data files during use.
Related calculators
Formula sources and references
References support the underlying methods and units. Chosen example inputs are not universal recommendations, supplier ratings, market prices or code limits.
- US EPA — EPANET 2.2 User Manual, Chapter 3: The Network Modelhttps://raw.githubusercontent.com/USEPA/EPANET2.2/master/User_Manual/docs/3_network_model.rst
- NIST Guide to the SI: conversion factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors