Pipe Flow CalculatorFlow, pressure & pipe geometry

Pipe calculators / Gas, air & steam

Define the pipe. Follow the flow.

Pipe Fanno Flow Calculator

Solve subsonic constant-area ideal-gas Fanno outlet Mach and friction-limited sonic length.

Your pipe & operating inputs

mm
m

Starting values are editable examples. Verify actual bore, fluid state and model assumptions. Dimension switching converts only the labelled length fields; flow and property units stay as printed.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

F(M)=(1−M²)/(γM²)+(γ+1)/(2γ) ln[(γ+1)M²/(2+(γ−1)M²)]; F(Mout)=F(Min)−fD L/D.

Solve subsonic constant-area ideal-gas Fanno outlet Mach and friction-limited sonic length.

  1. Confirm the fluid state, geometry, flow regime and units.
  2. Enter actual dimensions and justified operating conditions.
  3. Submit the form, then interpret the result with the assumptions and limits below.

Adiabatic perfect gas, no heat exchange, constant Darcy factor. A pipe longer than the critical length is rejected for the specified inlet state; it is not silently capped at Mach 1.

Pipe Fanno Flow: assumptions and applications

Solve subsonic constant-area ideal-gas Fanno outlet Mach and friction-limited sonic length. Adiabatic perfect gas, no heat exchange, constant Darcy factor. A pipe longer than the critical length is rejected for the specified inlet state; it is not silently capped at Mach 1.

Use the actual measured bore rather than assuming a nominal pipe label equals its inside diameter. Schedule, lining, corrosion and deposits can change the effective flow area. Enter the applicable fluid properties at the operating temperature.

A flow rate, velocity, pressure difference and capacity describe different physical quantities. The stated model determines which additional measurements are needed. The calculated examples below vary one input while holding all other printed values fixed.

Check the numbers

Pipe Fanno Flow Calculator: calculated examples

These scenarios are computed with the same method as the form. They are not product recommendations, code design values or complete standards tables.

Worked example with stated inputs

Dimension units = Metric (m / mm); Actual inside diameter = 50 mm; Straight pipe length = 1 m; Subsonic inlet Mach number = 0.2 ; Specific heat ratio = 1.4 ; Darcy friction factor = 0.02 .

OutputComputed result
Subsonic Fanno outlet Mach0.202396 Mach
Critical length for specified inlet36.333166 m
Outlet / inlet static temperature0.999809
Outlet / inlet static pressure0.988068

How the stated input changes the result

ScenarioChanged input / basisResult
0.5 mStraight pipe length0.201187 Mach
0.75 mStraight pipe length0.201788 Mach
1 mStraight pipe length0.202396 Mach
1.25 mStraight pipe length0.203009 Mach
1.5 mStraight pipe length0.203628 Mach
2 mStraight pipe length0.204883 Mach

Unchanged inputs use: Dimension units = Metric (m / mm); Actual inside diameter = 50 mm; Straight pipe length = 1 m; Subsonic inlet Mach number = 0.2 ; Specific heat ratio = 1.4 ; Darcy friction factor = 0.02 . Results retain the model limitations described above.

Common questions

Is Fanno flow the same as nozzle choking?

No. Fanno flow has constant area and wall friction with an adiabatic perfect gas. Isentropic nozzle choking uses a different geometry and energy model.

Why can the pipe exceed its calculated sonic length?

For the given inlet Mach, friction and bore, a longer pipe cannot retain that inlet state on this subsonic branch. A real system would need different boundary conditions; the solver reports an error.

How do I use this pipe fanno flow calculator?

Solve subsonic constant-area ideal-gas Fanno outlet Mach and friction-limited sonic length. F(M)=(1−M²)/(γM²)+(γ+1)/(2γ) ln[(γ+1)M²/(2+(γ−1)M²)]; F(Mout)=F(Min)−fD L/D.

Can I calculate in metric and imperial units?

The dimension selector converts the labelled length inputs. Flow and property inputs retain their explicitly printed units. Results include related units where meaningful; US gallons and Imperial gallons are different units.

Can I export this calculation to Excel?

Calculate first, then use Export CSV for results and inputs. This is a numeric text export, not an Excel formula workbook, desktop application or certified engineering report.

What do the starting values mean?

They are editable numerical examples. Actual bore, fluid state, roughness, geometry and boundary conditions must match the installation. A calculated result is not a pressure rating or code sizing approval.

Where are the formula sources?

The sources below show plain-text addresses. Equations, examples and tables are stored in these pages; the calculator does not fetch source websites or JSON data files during use.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, supplier ratings, market prices or code limits.

  • Penn State, John M. Cimbala: Fluid Mechanics Lesson 15H, Fanno Flowhttps://www.me.psu.edu/cimbala/me320/Lesson_Notes/Fluid_Mechanics_Lesson_15H.pdf
  • MathWorks: Fanno Flow Gas Pipe Validationhttps://www.mathworks.com/help/simscape/ug/fanno-flow-gas-pipe-validation.html
  • NIST Guide to the SI: conversion factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors