Pipe calculators / Pipe materials
Define the pipe. Follow the flow.
PEX Pipe Pressure Drop Calculator
Evaluate pex full-pipe pressure drop using actual bore and an editable resistance example. Smooth plastic example; fitting restrictions can exceed straight-tube resistance.
Your pipe & operating inputs
Your result
Ready to calculateEnter your values and press Calculate. The result will open on the calculation page.
Published references · Clear assumptions · No sign-up
The method
Formula and calculation steps
Δp = (fD L/D + ΣK) ρv²/2; Re = vD/ν. Laminar fD=64/Re; turbulent fD solves Colebrook.
Evaluate pex full-pipe pressure drop using actual bore and an editable resistance example. Smooth plastic example; fitting restrictions can exceed straight-tube resistance.
- Confirm the fluid state, geometry, flow regime and units.
- Enter actual dimensions and justified operating conditions.
- Submit the form, then interpret the result with the assumptions and limits below.
Steady, full, circular, single-phase incompressible flow. Reynolds numbers from 2000 through 4000 are deliberately rejected; this calculator does not interpolate uncertain transition flow. Roughness/diameter must not exceed 0.05. Smooth plastic example; fitting restrictions can exceed straight-tube resistance.
PEX Pipe Pressure Drop: assumptions and applications
Smooth plastic example; fitting restrictions can exceed straight-tube resistance. A material name does not fix the bore or pressure class. This page presets only the stated editable resistance input.
Δp = (fD L/D + ΣK) ρv²/2; Re = vD/ν. Laminar fD=64/Re; turbulent fD solves Colebrook. The comparison table varies straight length at the same operating fluid state, actual diameter and available pressure or flow.
For pex, check joint restrictions, coatings, deposits and temperature against the actual product. Nominal sizing charts and installation rules require their own specifications.
Continue with: PVC Pipe Flow Calculator · PVC Pipe Pressure Drop Calculator · HDPE Pipe Flow Calculator · HDPE Pipe Pressure Drop Calculator
Check the numbers
PEX Pipe Pressure Drop Calculator: calculated examples
These scenarios are computed with the same method as the form. They are not product recommendations, code design values or complete standards tables.
Worked example with stated inputs
Dimension units = Metric (m / mm); Actual inside diameter = 50 mm; Straight pipe length = 30 m; Absolute roughness (example) = 0.0015 mm; Sum of minor-loss K = 0 ; Fluid density = 998.2 kg/m³; Kinematic viscosity = 1.004 mm²/s; Actual volume flow = 2 L/s.
| Output | Computed result |
|---|---|
| Friction pressure loss | 6.503993 kPa |
| Pressure loss | 6.503993 kPa |
| Pressure loss | 0.943325 psi |
| Fluid head loss | 0.664419 m |
| Mean velocity | 1.018592 m/s |
| Reynolds number | 50,726.675089 |
| Darcy friction factor | 0.020933 |
| Relative roughness | 3.0e-5 |
| Actual flow | 2 L/s |
| Actual flow | 7.2 m³/h |
| US gallons per minute | 31.700646 US gpm |
| Imperial gallons per minute | 26.39631 Imp gpm |
| Actual cubic feet per minute | 4.23776 acfm |
How the stated input changes the result
| Scenario | Changed input / basis | Result |
|---|---|---|
| 15 m | Straight pipe length | 3.251997 kPa |
| 22.5 m | Straight pipe length | 4.877995 kPa |
| 30 m | Straight pipe length | 6.503993 kPa |
| 37.5 m | Straight pipe length | 8.129992 kPa |
| 45 m | Straight pipe length | 9.75599 kPa |
| 60 m | Straight pipe length | 13.007987 kPa |
Unchanged inputs use: Dimension units = Metric (m / mm); Actual inside diameter = 50 mm; Straight pipe length = 30 m; Absolute roughness (example) = 0.0015 mm; Sum of minor-loss K = 0 ; Fluid density = 998.2 kg/m³; Kinematic viscosity = 1.004 mm²/s; Actual volume flow = 2 L/s. Results retain the model limitations described above.
Common questions
What is the difference between major and minor losses?
Major loss is distributed wall friction over straight length. Minor loss represents fittings, entrances and other local features using coefficients referenced to the appropriate velocity.
How do pipe length and flow change pressure drop?
At a fixed flow and bore, straight-pipe friction increases with length. Flow changes both velocity and Reynolds-dependent friction, so pressure drop is not generally proportional to flow.
Is 0.0015 mm a guaranteed PEX roughness?
No. This editable value is an illustrative resistance input, not a certified material constant. Obtain condition-specific roughness and actual bore before using the result.
How do I use this pex pipe pressure drop calculator?
Evaluate pex full-pipe pressure drop using actual bore and an editable resistance example. Smooth plastic example; fitting restrictions can exceed straight-tube resistance. Δp = (fD L/D + ΣK) ρv²/2; Re = vD/ν. Laminar fD=64/Re; turbulent fD solves Colebrook.
Can I calculate in metric and imperial units?
The dimension selector converts the labelled length inputs. Flow and property inputs retain their explicitly printed units. Results include related units where meaningful; US gallons and Imperial gallons are different units.
Can I export this calculation to Excel?
Calculate first, then use Export CSV for results and inputs. This is a numeric text export, not an Excel formula workbook, desktop application or certified engineering report.
What do the starting values mean?
They are editable numerical examples. Actual bore, fluid state, roughness, geometry and boundary conditions must match the installation. A calculated result is not a pressure rating or code sizing approval.
Where are the formula sources?
The sources below show plain-text addresses. Equations, examples and tables are stored in these pages; the calculator does not fetch source websites or JSON data files during use.
Related calculators
Formula sources and references
References support the underlying methods and units. Chosen example inputs are not universal recommendations, supplier ratings, market prices or code limits.
- US EPA — EPANET 2.2 User Manual, Chapter 3: The Network Modelhttps://raw.githubusercontent.com/USEPA/EPANET2.2/master/User_Manual/docs/3_network_model.rst
- US EPA — EPANET 2.2 User Manual, Chapter 12: Analysis Algorithmshttps://raw.githubusercontent.com/USEPA/EPANET2.2/master/User_Manual/docs/12_analysis_algorithms.rst
- Brkić and Praks (2019) — Accurate and Efficient Explicit Approximations of the Colebrook Flow Friction Equation Based on the Wright ω-Functionhttps://www.mdpi.com/2227-7390/7/1/34
- NIST Guide to the SI: conversion factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors