Pipe Flow CalculatorFlow, pressure & pipe geometry

Pipe calculators / Gas, air & steam

Define the pipe. Follow the flow.

Natural Gas Pipe Bore Sizing Calculator

Solve a continuous natural gas bore for entered mass flow and pressure endpoints.

Your pipe & operating inputs

m
kPa absolute
kPa absolute
K
J/(kg·K)
kg/h

Starting values are editable examples. Verify actual bore, fluid state and model assumptions. Dimension switching converts only the labelled length fields; flow and property units stay as printed.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

D=[16 fD L ṁ² ZRT/(π²(p1²−p2²))]^(1/5).

Solve a continuous natural gas bore for entered mass flow and pressure endpoints.

  1. Confirm the fluid state, geometry, flow regime and units.
  2. Enter actual dimensions and justified operating conditions.
  3. Submit the form, then interpret the result with the assumptions and limits below.

Horizontal steady isothermal single-phase gas, constant supplied Z and Darcy factor, no fittings. The reduced relation is restricted here to outlet speed/√(ZRT) ≤0.3; no fuel-gas code sizing or certified line capacity. This continuous bore is not a nominal or code-approved pipe size.

Natural Gas Pipe Bore Sizing: assumptions and applications

Solve a continuous natural gas bore for entered mass flow and pressure endpoints. Horizontal steady isothermal single-phase gas, constant supplied Z and Darcy factor, no fittings. The reduced relation is restricted here to outlet speed/√(ZRT) ≤0.3; no fuel-gas code sizing or certified line capacity. This continuous bore is not a nominal or code-approved pipe size.

Use the actual measured bore rather than assuming a nominal pipe label equals its inside diameter. Schedule, lining, corrosion and deposits can change the effective flow area. Enter the applicable fluid properties at the operating temperature.

A flow rate, velocity, pressure difference and capacity describe different physical quantities. The stated model determines which additional measurements are needed. The calculated examples below vary one input while holding all other printed values fixed.

Check the numbers

Natural Gas Pipe Bore Sizing Calculator: calculated examples

These scenarios are computed with the same method as the form. They are not product recommendations, code design values or complete standards tables.

Worked example with stated inputs

Dimension units = Metric (m / mm); Straight pipe length = 30 m; Upstream absolute pressure = 700 kPa absolute; Downstream absolute pressure = 680 kPa absolute; Gas temperature = 293.15 K; Specific gas constant = 518.3 J/(kg·K); Constant compressibility factor Z = 1 ; Darcy friction factor (entered) = 0.02 ; Gas mass flow = 20 kg/h.

OutputComputed result
Continuous isothermal gas bore11.05701 mm bore
Downstream absolute pressure680 kPa absolute
Inside diameter11.05701 mm
Outlet velocity12.927794 m/s
Outlet speed / sqrt(ZRT)0.033166

How the stated input changes the result

ScenarioChanged input / basisResult
10 kg/hGas mass flow8.379647 mm bore
15 kg/hGas mass flow9.855127 mm bore
20 kg/hGas mass flow11.05701 mm bore
25 kg/hGas mass flow12.089315 mm bore
30 kg/hGas mass flow13.003917 mm bore
40 kg/hGas mass flow14.589812 mm bore

Unchanged inputs use: Dimension units = Metric (m / mm); Straight pipe length = 30 m; Upstream absolute pressure = 700 kPa absolute; Downstream absolute pressure = 680 kPa absolute; Gas temperature = 293.15 K; Specific gas constant = 518.3 J/(kg·K); Constant compressibility factor Z = 1 ; Darcy friction factor (entered) = 0.02 ; Gas mass flow = 20 kg/h. Results retain the model limitations described above.

Common questions

Is the calculated gas bore a recommended pipe size?

No. It is the continuous bore from fixed Darcy factor and stated pressure endpoints. Actual pipe selections and code equivalent lengths need independent verification.

Does a 2 psi natural-gas system use 2 psi absolute?

No. A 2 psi gauge supply is approximately 2 psi above local atmospheric pressure. Use absolute pressure at both endpoints and a suitable actual gas composition.

How do I use this natural gas pipe bore sizing calculator?

Solve a continuous natural gas bore for entered mass flow and pressure endpoints. D=[16 fD L ṁ² ZRT/(π²(p1²−p2²))]^(1/5).

Can I calculate in metric and imperial units?

The dimension selector converts the labelled length inputs. Flow and property inputs retain their explicitly printed units. Results include related units where meaningful; US gallons and Imperial gallons are different units.

Can I export this calculation to Excel?

Calculate first, then use Export CSV for results and inputs. This is a numeric text export, not an Excel formula workbook, desktop application or certified engineering report.

What do the starting values mean?

They are editable numerical examples. Actual bore, fluid state, roughness, geometry and boundary conditions must match the installation. A calculated result is not a pressure rating or code sizing approval.

Where are the formula sources?

The sources below show plain-text addresses. Equations, examples and tables are stored in these pages; the calculator does not fetch source websites or JSON data files during use.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, supplier ratings, market prices or code limits.

  • Kowalczuk and Tatara (2020), Improved model of isothermal and incompressible fluid flow in pipelines versus the Darcy-Weisbach equation and the issue of friction factorhttps://doi.org/10.1017/jfm.2020.131
  • NASA Glenn: Equation of Statehttps://www1.grc.nasa.gov/beginners-guide-to-aeronautics/equation-of-state/
  • NIST Guide to the SI: conversion factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors