Pipe Flow CalculatorFlow, pressure & pipe geometry

Pipe calculators / Gas, air & steam

Define the pipe. Follow the flow.

Gas Heating Value Flow Calculator

Convert fuel heat input to a reference-volume gas demand using an entered heating value.

Your pipe & operating inputs

BTU/h
BTU/reference ft³

Starting values are editable examples. Verify actual bore, fluid state and model assumptions. Dimension switching converts only the labelled length fields; flow and property units stay as printed.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

Reference gas flow=heat input/heating value.

Convert fuel heat input to a reference-volume gas demand using an entered heating value.

  1. Confirm the fluid state, geometry, flow regime and units.
  2. Enter actual dimensions and justified operating conditions.
  3. Submit the form, then interpret the result with the assumptions and limits below.

Use a consistent HHV or LHV and gas reference state. Demand alone does not select a pipe diameter or prove allowable pressure drop.

Gas Heating Value Flow: assumptions and applications

Convert fuel heat input to a reference-volume gas demand using an entered heating value. Use a consistent HHV or LHV and gas reference state. Demand alone does not select a pipe diameter or prove allowable pressure drop.

Use the actual measured bore rather than assuming a nominal pipe label equals its inside diameter. Schedule, lining, corrosion and deposits can change the effective flow area. Enter the applicable fluid properties at the operating temperature.

A flow rate, velocity, pressure difference and capacity describe different physical quantities. The stated model determines which additional measurements are needed. The calculated examples below vary one input while holding all other printed values fixed.

Check the numbers

Gas Heating Value Flow Calculator: calculated examples

These scenarios are computed with the same method as the form. They are not product recommendations, code design values or complete standards tables.

Worked example with stated inputs

Fuel heat input = 100000 BTU/h; Gas heating value at reference state = 1000 BTU/reference ft³.

OutputComputed result
Gas demand at heating-value reference100 reference ft³/h
Reference volume demand2.831685 reference m³/h

How the stated input changes the result

ScenarioChanged input / basisResult
50000 BTU/hFuel heat input50 reference ft³/h
75000 BTU/hFuel heat input75 reference ft³/h
100000 BTU/hFuel heat input100 reference ft³/h
125000 BTU/hFuel heat input125 reference ft³/h
150000 BTU/hFuel heat input150 reference ft³/h
200000 BTU/hFuel heat input200 reference ft³/h

Unchanged inputs use: Fuel heat input = 100000 BTU/h; Gas heating value at reference state = 1000 BTU/reference ft³. Results retain the model limitations described above.

Common questions

What is the main limitation of this calculation?

Use a consistent HHV or LHV and gas reference state. Demand alone does not select a pipe diameter or prove allowable pressure drop.

How are the comparison-table numbers generated?

Each row changes the labelled fuel heat input from the worked example. The other printed inputs remain fixed. The table uses the same Reference gas flow=heat input/heating value. method as the form.

How do I use this gas heating value flow calculator?

Convert fuel heat input to a reference-volume gas demand using an entered heating value. Reference gas flow=heat input/heating value.

Can I calculate in metric and imperial units?

The dimension selector converts the labelled length inputs. Flow and property inputs retain their explicitly printed units. Results include related units where meaningful; US gallons and Imperial gallons are different units.

Can I export this calculation to Excel?

Calculate first, then use Export CSV for results and inputs. This is a numeric text export, not an Excel formula workbook, desktop application or certified engineering report.

What do the starting values mean?

They are editable numerical examples. Actual bore, fluid state, roughness, geometry and boundary conditions must match the installation. A calculated result is not a pressure rating or code sizing approval.

Where are the formula sources?

The sources below show plain-text addresses. Equations, examples and tables are stored in these pages; the calculator does not fetch source websites or JSON data files during use.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, supplier ratings, market prices or code limits.

  • Spirax Sarco: Methods of Estimating Steam Consumptionhttps://www.spiraxsarco.com/learn-about-steam/steam-engineering-principles-and-heat-transfer/methods-of-estimating-steam-consumption
  • NIST Guide to the SI: conversion factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors