Pipe Flow CalculatorFlow, pressure & pipe geometry

Pipe calculators / Pipe materials

Define the pipe. Follow the flow.

Corrugated Metal Pipe Flow Calculator

Evaluate corrugated metal full-pipe flow using actual bore and an editable resistance example. Illustrative entered roughness only; corrugation profile and condition require manufacturer data.

Your pipe & operating inputs

mm
m
mm
kg/m³
mm²/s
kPa

Starting values are editable examples. Verify actual bore, fluid state and model assumptions. Dimension switching converts only the labelled length fields; flow and property units stay as printed.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

Δp = (fD L/D + ΣK) ρv²/2; Re = vD/ν. Laminar fD=64/Re; turbulent fD solves Colebrook.

Evaluate corrugated metal full-pipe flow using actual bore and an editable resistance example. Illustrative entered roughness only; corrugation profile and condition require manufacturer data.

  1. Confirm the fluid state, geometry, flow regime and units.
  2. Enter actual dimensions and justified operating conditions.
  3. Submit the form, then interpret the result with the assumptions and limits below.

Steady, full, circular, single-phase incompressible flow. Reynolds numbers from 2000 through 4000 are deliberately rejected; this calculator does not interpolate uncertain transition flow. Roughness/diameter must not exceed 0.05. Illustrative entered roughness only; corrugation profile and condition require manufacturer data.

Corrugated Metal Pipe Flow: assumptions and applications

Illustrative entered roughness only; corrugation profile and condition require manufacturer data. A material name does not fix the bore or pressure class. This page presets only the stated editable resistance input.

Δp = (fD L/D + ΣK) ρv²/2; Re = vD/ν. Laminar fD=64/Re; turbulent fD solves Colebrook. The comparison table varies straight length at the same operating fluid state, actual diameter and available pressure or flow.

For corrugated metal, check joint restrictions, coatings, deposits and temperature against the actual product. Nominal sizing charts and installation rules require their own specifications.

Check the numbers

Corrugated Metal Pipe Flow Calculator: calculated examples

These scenarios are computed with the same method as the form. They are not product recommendations, code design values or complete standards tables.

Worked example with stated inputs

Dimension units = Metric (m / mm); Actual inside diameter = 50 mm; Straight pipe length = 30 m; Absolute roughness (example) = 1 mm; Sum of minor-loss K = 0 ; Fluid density = 998.2 kg/m³; Kinematic viscosity = 1.004 mm²/s; Available friction pressure difference = 50 kPa.

OutputComputed result
Flow for available friction pressure3.622253 L/s
Pressure loss50 kPa
Pressure loss7.251887 psi
Fluid head loss5.107775 m
Mean velocity1.844798 m/s
Reynolds number91,872.430796
Darcy friction factor0.049061
Relative roughness0.02
Actual flow3.622253 L/s
Actual flow13.040112 m³/h
US gallons per minute57.413884 US gpm
Imperial gallons per minute47.807059 Imp gpm
Actual cubic feet per minute7.67512 acfm

How the stated input changes the result

ScenarioChanged input / basisResult
15 mStraight pipe length5.129101 L/s
22.5 mStraight pipe length4.185027 L/s
30 mStraight pipe length3.622253 L/s
37.5 mStraight pipe length3.238203 L/s
45 mStraight pipe length2.954712 L/s
60 mStraight pipe length2.556787 L/s

Unchanged inputs use: Dimension units = Metric (m / mm); Actual inside diameter = 50 mm; Straight pipe length = 30 m; Absolute roughness (example) = 1 mm; Sum of minor-loss K = 0 ; Fluid density = 998.2 kg/m³; Kinematic viscosity = 1.004 mm²/s; Available friction pressure difference = 50 kPa. Results retain the model limitations described above.

Common questions

How do I calculate water flow from PSI and pipe size?

Enter pressure available for friction, actual inside diameter, length, roughness, local-loss K, density and viscosity. The solver finds the supported laminar or turbulent flow branch.

Does this calculate maximum pipe flow?

Only the flow for the entered pressure and model assumptions. Other limits such as allowed speed, noise, cavitation, surge and pump operation are not optimized.

Is 1 mm a guaranteed Corrugated Metal roughness?

No. This editable value is an illustrative resistance input, not a certified material constant. Obtain condition-specific roughness and actual bore before using the result.

How do I use this corrugated metal pipe flow calculator?

Evaluate corrugated metal full-pipe flow using actual bore and an editable resistance example. Illustrative entered roughness only; corrugation profile and condition require manufacturer data. Δp = (fD L/D + ΣK) ρv²/2; Re = vD/ν. Laminar fD=64/Re; turbulent fD solves Colebrook.

Can I calculate in metric and imperial units?

The dimension selector converts the labelled length inputs. Flow and property inputs retain their explicitly printed units. Results include related units where meaningful; US gallons and Imperial gallons are different units.

Can I export this calculation to Excel?

Calculate first, then use Export CSV for results and inputs. This is a numeric text export, not an Excel formula workbook, desktop application or certified engineering report.

What do the starting values mean?

They are editable numerical examples. Actual bore, fluid state, roughness, geometry and boundary conditions must match the installation. A calculated result is not a pressure rating or code sizing approval.

Where are the formula sources?

The sources below show plain-text addresses. Equations, examples and tables are stored in these pages; the calculator does not fetch source websites or JSON data files during use.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, supplier ratings, market prices or code limits.

  • US EPA — EPANET 2.2 User Manual, Chapter 3: The Network Modelhttps://raw.githubusercontent.com/USEPA/EPANET2.2/master/User_Manual/docs/3_network_model.rst
  • US EPA — EPANET 2.2 User Manual, Chapter 12: Analysis Algorithmshttps://raw.githubusercontent.com/USEPA/EPANET2.2/master/User_Manual/docs/12_analysis_algorithms.rst
  • Brkić and Praks (2019) — Accurate and Efficient Explicit Approximations of the Colebrook Flow Friction Equation Based on the Wright ω-Functionhttps://www.mdpi.com/2227-7390/7/1/34
  • NIST Guide to the SI: conversion factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors