Pipe Flow CalculatorFlow, pressure & pipe geometry

Pipe calculators / Pipe materials

Define the pipe. Follow the flow.

Cast Iron Pipe Pressure Drop Calculator

Evaluate cast iron full-pipe pressure drop using actual bore and an editable resistance example. New cast-iron illustration; aged pipe requires condition-specific data.

Your pipe & operating inputs

mm
m
mm
kg/m³
mm²/s
L/s

Starting values are editable examples. Verify actual bore, fluid state and model assumptions. Dimension switching converts only the labelled length fields; flow and property units stay as printed.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

Δp = (fD L/D + ΣK) ρv²/2; Re = vD/ν. Laminar fD=64/Re; turbulent fD solves Colebrook.

Evaluate cast iron full-pipe pressure drop using actual bore and an editable resistance example. New cast-iron illustration; aged pipe requires condition-specific data.

  1. Confirm the fluid state, geometry, flow regime and units.
  2. Enter actual dimensions and justified operating conditions.
  3. Submit the form, then interpret the result with the assumptions and limits below.

Steady, full, circular, single-phase incompressible flow. Reynolds numbers from 2000 through 4000 are deliberately rejected; this calculator does not interpolate uncertain transition flow. Roughness/diameter must not exceed 0.05. New cast-iron illustration; aged pipe requires condition-specific data.

Cast Iron Pipe Pressure Drop: assumptions and applications

New cast-iron illustration; aged pipe requires condition-specific data. A material name does not fix the bore or pressure class. This page presets only the stated editable resistance input.

Δp = (fD L/D + ΣK) ρv²/2; Re = vD/ν. Laminar fD=64/Re; turbulent fD solves Colebrook. The comparison table varies straight length at the same operating fluid state, actual diameter and available pressure or flow.

For cast iron, check joint restrictions, coatings, deposits and temperature against the actual product. Nominal sizing charts and installation rules require their own specifications.

Check the numbers

Cast Iron Pipe Pressure Drop Calculator: calculated examples

These scenarios are computed with the same method as the form. They are not product recommendations, code design values or complete standards tables.

Worked example with stated inputs

Dimension units = Metric (m / mm); Actual inside diameter = 50 mm; Straight pipe length = 30 m; Absolute roughness (example) = 0.26 mm; Sum of minor-loss K = 0 ; Fluid density = 998.2 kg/m³; Kinematic viscosity = 1.004 mm²/s; Actual volume flow = 2 L/s.

OutputComputed result
Friction pressure loss10.089029 kPa
Pressure loss10.089029 kPa
Pressure loss1.46329 psi
Fluid head loss1.03065 m
Mean velocity1.018592 m/s
Reynolds number50,726.675089
Darcy friction factor0.032472
Relative roughness0.0052
Actual flow2 L/s
Actual flow7.2 m³/h
US gallons per minute31.700646 US gpm
Imperial gallons per minute26.39631 Imp gpm
Actual cubic feet per minute4.23776 acfm

How the stated input changes the result

ScenarioChanged input / basisResult
15 mStraight pipe length5.044515 kPa
22.5 mStraight pipe length7.566772 kPa
30 mStraight pipe length10.089029 kPa
37.5 mStraight pipe length12.611286 kPa
45 mStraight pipe length15.133544 kPa
60 mStraight pipe length20.178058 kPa

Unchanged inputs use: Dimension units = Metric (m / mm); Actual inside diameter = 50 mm; Straight pipe length = 30 m; Absolute roughness (example) = 0.26 mm; Sum of minor-loss K = 0 ; Fluid density = 998.2 kg/m³; Kinematic viscosity = 1.004 mm²/s; Actual volume flow = 2 L/s. Results retain the model limitations described above.

Common questions

What is the difference between major and minor losses?

Major loss is distributed wall friction over straight length. Minor loss represents fittings, entrances and other local features using coefficients referenced to the appropriate velocity.

How do pipe length and flow change pressure drop?

At a fixed flow and bore, straight-pipe friction increases with length. Flow changes both velocity and Reynolds-dependent friction, so pressure drop is not generally proportional to flow.

Is 0.26 mm a guaranteed Cast Iron roughness?

No. This editable value is an illustrative resistance input, not a certified material constant. Obtain condition-specific roughness and actual bore before using the result.

How do I use this cast iron pipe pressure drop calculator?

Evaluate cast iron full-pipe pressure drop using actual bore and an editable resistance example. New cast-iron illustration; aged pipe requires condition-specific data. Δp = (fD L/D + ΣK) ρv²/2; Re = vD/ν. Laminar fD=64/Re; turbulent fD solves Colebrook.

Can I calculate in metric and imperial units?

The dimension selector converts the labelled length inputs. Flow and property inputs retain their explicitly printed units. Results include related units where meaningful; US gallons and Imperial gallons are different units.

Can I export this calculation to Excel?

Calculate first, then use Export CSV for results and inputs. This is a numeric text export, not an Excel formula workbook, desktop application or certified engineering report.

What do the starting values mean?

They are editable numerical examples. Actual bore, fluid state, roughness, geometry and boundary conditions must match the installation. A calculated result is not a pressure rating or code sizing approval.

Where are the formula sources?

The sources below show plain-text addresses. Equations, examples and tables are stored in these pages; the calculator does not fetch source websites or JSON data files during use.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, supplier ratings, market prices or code limits.

  • US EPA — EPANET 2.2 User Manual, Chapter 3: The Network Modelhttps://raw.githubusercontent.com/USEPA/EPANET2.2/master/User_Manual/docs/3_network_model.rst
  • US EPA — EPANET 2.2 User Manual, Chapter 12: Analysis Algorithmshttps://raw.githubusercontent.com/USEPA/EPANET2.2/master/User_Manual/docs/12_analysis_algorithms.rst
  • Brkić and Praks (2019) — Accurate and Efficient Explicit Approximations of the Colebrook Flow Friction Equation Based on the Wright ω-Functionhttps://www.mdpi.com/2227-7390/7/1/34
  • NIST Guide to the SI: conversion factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors